| Place of Origin |
Jiangsu China (Mainland) |
| Brand Name |
DANHE |
| Model Number |
QCC26C 400A/10 |
| Electricity Type |
DC |
| Number of Pole |
1 |
| Phase |
1 |
| Main Circuit Rating Current |
400a |
ParametersModelQCC26C-400A/10Coil rated voltage(DC)1224364872Main contact current rated voltage(DC)Without magnetic blow-out Inductive load 48 Resistive load 60 With magnetic blow-out and polarity Inductive load 96 Resistive load 120 Main contact circuit rated load current (A)400Coil rated current(A)1.500.720.650.600.20Cold action voltage(V)Close≥60%Release≥5% 30%Max. action time (ms) (coil without restraint circuit)Close40Release40Weight(kg)1.20